ANALYZER OF LIQUID FLOW CONTAMINATION FOTON-965.2/3/4/5/6/7
Analyzer FOTON-965 is intended for the measurements of the contamination concentration in dimensional groups in accordance with standard GOST 17216-2001. Last digit in the name of the device means the quantity of sensors in analyzer. Analyzer determines the purity class of liquid due to the number of particles of different size, that can be registrated by the analyzer. FOTON-965 also can be used for the diagnostics of hydraulic systems and machinery on the parameters of wear debris. FOTON-965 may be used in aircraft, spacecraft, automotive industry etc.
FOTON-965 may be installed in locations without explosive and deflagrable substances. Built-in sensors of FOTON-965 are installed in hydraulic main of the technological equipment. FOTON-965 performs continuous monitoring of liquid purity in different points of hydraulic systems, for example, after pump, at the inlet and outlet of aggregate tested and additionally at the outlet of the heat exchanger.
SPECIFICATION
| Types of controllable liquids - hydraulic and transformer oils and other liquids with viscosity at the operating temperature mm2/s, not more | 20 |
| Temperature of controllable media, o C | 5...60 |
| Flow of liquid in the main, m3/h | 0.3...4.2 |
| Working pressure, MPa | 0.3...28 |
| Hydraulic resistance of the sensor at the flow 3 m3/h, not more, MPa | 0.1 |
| Size range of particles to be controlled (diameter), micrometers | 5... 10 10... 25 25... 50 50... 100 100...200 more than 200 |
| Maximum of the main concentration measurement error, % | +-20 |
| Maximum of the size measurement error, related to the size boundaries, % | 10 |
| Additional concentration measurement error at the concentration 1500 cm-3, %, not more | 15 |
| Consumed power, not more, VA | 50 |
| Dimensions, mm:
- sensor - electronic unit |
100x110x190 210x310x150 |